The spinal needles are cannulas for spinal puncture with conical-elliptic shaped tip with oval lateral orifice made out of medical grading stainless steel with a transparent handle in polycarbonate.

Non-traumatic pencil point tip to reduce the risk of nerve fibre damage and favour the transmission of the perforation click of the Dura Mater to the needle hub.

REF-NRDIAMETERLENGTHINTRODUCERCOLOUR CODE UNITS / BOX
21951-21*21G90 mm30 mmGREEN25
31950-21*21G123 mm38 mmGREEN25
21951-2222G90 mm30 mmBLACK25
21950-22 22G103 mm38 mmBLACK25
31940-2222G150 mm42 mmBLACK25
21951-2424G90 mm30 mmLILAC BLUE25
21950-2424G103 mm38 mmLILAC BLUE25
31940-24 24G150 mm 42 mmLILAC BLUE25
31951-2424G123 mm 42 mmLILAC BLUE25
21951-2525G90 mm30 mmORANGE25
21950-2525G103 mm38 mmORANGE25
21950-25P25G103 mm38 mmORANGE25
31951-2525G123 mm42 mmORANGE25
31940-2525G150 mm42 mmORANGE25
21951-2626G90 mm30 mmBROWN25
21950-2626G103 mm38 mmBROWN25
21951-2727G90 mm30 mmGREY25
21950-2727G103 mm38 mmGREY25
21951-2929G90 mm30 mmRED25
21950-2929G103 mm38 mmRED25
kid-aguja-espinal-punta-lapiz-pediatria-temena-group

The spinal needles with Quincke bevel are cannulas for spinal puncture with introducer double bevel (20°/30°) to reduce the patient’s pain thanks to a rapid penetration; the needles are made of stainless steel of medical quality with a transparent handle in polycarbonate.

The stylet hub presents a color code in accordance with the diameter of the needle. A syringe can be attached to the needle in order to inject an anesthetic product.

REF-NRDIAMETERLENGTHINTRODUCTORCOLOUR CODE UNITS BOX
20118-09018G90 mmNoLIGHT PINK25
20120-09020G90 mmNoYELLOW25
20122-04022G38 mmNoBLACK25
20122-06522G65 mmNoBLACK25
20122-09022G90 mmNoBLACK25
21125-09025G90 mm30 mmORANGE25
21127-09027G90 mm30 mmGREY25
21129-09029G90 mm30 mmRED25
Aguja espinal bisel Quincke

The Tuohy epidural needles provide high precision positioning in the epidural space, enable a clear perception of the tissue during insertion.

Tuohy needle incorporates a centimetric marking on the tube to control the depth of penetration of the needle.

REF-NRDIAMETERLENGTHCOLOR CODE UNITS / BOX
98090-1717G90 mmRED25
98080-1818G80 mmPINK25
98090-1818G90 mmPINK25
98120-1818G120 mmPINK25
98150-1818G150 mmPINK25
98045-2020G45 mmYELLOW25
98090-2020G90 mmYELLOW25
98090-2121G90 mmGREEN25
Tuohy epidural needle temena

The Polystim II peripheral nerve stimulator offers digital functions, a digital screen, a stimulation field from 0 to 5 mA, with 3 adjustable lengths of stimulating impulses.

These features allow the peripheral nerve to be located rapidly. The actual current transmitted to the patient can be checked simultaneously.

REF-NRNAMEDESCRIPTIONUNITS / BOX
27050-01Polystim IIStimulator with accessories : monopolar connecting cable, alkaline battery, user’s manual, protecting plastic box.1
07050-02Monopolar connecting cableMonopolar connecting cable1
Polystim II; nerve stimulator; neuroestimulador

The UPC stimulation needle offers a 20º bevel, the design of which allows easy penetration. Only the extreme tip of the needle is not insulated and stimulates, providing a reduced stimulation field and a higher precision.

With their 2 mm female electric connection, the needles are compatible with all standard peripheral nerve stimulators.

REF-NRNAMEDIAMETERLENGTHUNITS / BOX
92025-24UPC 2524G25 mm10
92035-24UPC 3524G35 mm10
92050-22UPC 5022G50 mm10
92050-23UPC 5023G50 mm10
92070-23UPC 7023G70 mm10
92070-22UPC 7022G70 mm10
92090-22UPC 9022G90 mm10
92090-21UPC 9021G90 mm10
92120-21UPC12021G120 mm10
92150-21UPC 15021G150 mm10
UPC Estimulación Temena

The UPM stimulation needle offers a short 45º bevel. Stimulating area includes the entire needle bevel. Its overmoulded ergonomic hub covers the connection between the needle, the extension tube and the connecting cable, avoiding any leak of liquid.

With their 2 mm female electric connection, the needles are compatible with all standard peripheral nerve stimulators.

REF-NRNAMEDIAMETERLENGTHUNITS / BOX
82025-24UPM 25 24G25 mm10
82050-22UPM 50 22G50 mm10
82070-22 UPM 7022G70 mm 10
82090-21UPM 9021G90 mm10
82120-21UPM 12021G120 mm10
82150-21UPM 15021G150 mm10
UPM Estimulación Temena

Our << Block Needle >> is designed to Is designed for the realization of emergency tactile blocks. This needle is provided with a 45 ° bevel. This needle does not require an ultrasound machine or neurostimulator to perform a tactile block.

REF-NRDIAMETERLENGTHEXTENSION LINEUNITS/BOX
BN050-2222G50 mm600 mm10.0
BN025-2424G25 mm600 mm10.0
kid-block-needle-pediatria-temena-group

ILIO-SET offers our “block needle” 45º bevel with all the accessories available as in all the other polyplex sets.

REF-NRSIZE NEEDLE SIZES CATHETER STYLETCONNECTORFILTERACCESSORIESUNITS / BOX
BN118-5018 G x 50 mm21 G x 400 mm Teflon®TBA0,2μCatheter Fixation
Thread device
10
Ilio Set

Hybrid EVOLUTION needles have a 30º or 20º bevel allowing a puncture with little resistance. Peripheral nerve blocks can be performed by nerve
stimulation  or ultrasound technique. 

Characteristics 

  • This needle provides a high Visibility in different angles and depths (360º).
  • Easy recognition of the needle’s position thanks to centimetric marking.
REF-NRSIZELENGTH UNITS / BOX
EH035-2222 G35 mm 10
EH055-2222 G55 mm10
EH095-2121 G95 mm10
EH125-2121 G125 mm10
EH150-2121 G150 mm10
Hybrid EVOLUTION Temena

Hybrid EVOLUTION needles have a 30º or 20º bevel allowing a puncture with little resistance. Peripheral nerve blocks can be performed by nerve
stimulation  or ultrasound technique. 

Characteristics 

  • This needle provides a high Visibility in different angles and depths (360º).
  • Easy recognition of the needle’s position thanks to centimetric marking.
REF-NRSIZELENGTH UNITS / BOX
EHB035-2222 G (0.70 mm)35 mm10
EHB055-2222 G (0.70 mm)55 mm10
EHB095-2121 G (0.81 mm)95 mm10
EHB125-2121 G (0.81 mm)125 mm10
EHB150-2121 G (0.81 mm)150 mm10

EVOLUTION represents equals an improved version of ultrasound needle USB of Temena Group.

These needles have been designed specifically for the research of muscular nerve sheaths so you can see them clearly on the screen of an ultrasound machine thanks to a improved surface treatment of the steel tubing and a specially designed 30º bevel.

Characteristics 

  • This needle provides a high Visibility in different angles and depths (360º).
  • Easy recognition of the needle’s position thanks to centimetric
REF-NRSIZELENGTHPVC EXTENSION LINEUNITS / BOX
USB025-24
24 G
25 mm600 mm10
USB035-2424 G35 mm600 mm10
USB050-2424 G50 mm600 mm10
USB050-2222 G50 mm600 mm10
USB070-2222 G70 mm600 mm10
USB080-2222 G80 mm600 mm10
USB090-2121 G90 mm600 mm10
USB100-2121 G100 mm600 mm10
USB120-2121 G120 mm600 mm10
USB150-2121 G150 mm600 mm10
USC EVOLUTION Ultraosund needle Temena

EVOLUTION represents equals an improved version of ultrasound needle USC of Temena Group.

These needles have been designed specifically for the research of muscular nerve sheaths so you can see them clearly on the screen of an ultrasound machine thanks to a improved surface treatment of the steel tubing and a specially designed 20º bevel.

Characteristics 

  • This needle provides a high Visibility in different angles and depths (360º).
  • Easy recognition of the needle’s position thanks to centimetric
REF-NRSIZELENGTHPVC EXTENSION LINEUNITS / BOX
USC050-2222 G 50 mm600 mm10
USC070-22 22 G70 mm600 mm10
USC080-22 22 G80 mm600 mm10
USC090-2121 G90 mm600 mm10
USC100-2121 G100 mm600 mm10
USC120-2121 G120 mm600 mm10
USC150-2121 G150 mm600 mm10
USB EVOLUTION Temena Group

The multi-hole catheters infilcath make it possible to achieve an analgesia or anaesthesia thanks to a continuous infiltration for wider areas regardless of the length of the diffusion area and the
indication.

This perfect diffusion is possible thanks to of 6/12/21/48 holes the helicoidal distribution in diffusion areas from 20 – 332 mm.

REF-NRDIAMETERLENGTHSTYLETCONNECTORLENGTH OF THE DIFFUSION AREA NUMBER OF HOLES / DISTANCE UNITS/BOX
03590SB2020G900 mmTeflon®TBA20 mm6 holes at a distance of 4 mm.10
03590SA2020G900 mmTeflon®TBA66 mm6 holes distributed in 2 groups with 3 holes, with a distance of 4 mm between them and a distance of 50 mm between both groups.10
03590DB2020G900 mmTeflon®TBA70 mm12 holes distributed in 2 groups with 6 holes, with a distance of 4 mm between them and a distance of 30 mm between both groups.10
03590DA2020G900 mmTeflon®TBA120 mm12 holes distributed in 2 groups with 6 holes, with a distance of 4 mm between them and a distance of 80 mm between both groups.10
03590DG3619G900 mmTeflon®TBA143 mm21 holes with a distance of 4 mm between them at a length of 143 mm.10
03590DG8419G900 mmTeflon®TBA332 mm48 holes with a distance of 4 mm between them at a length of 332 mm.10
Catheter for continuous infiltration.

Set with Tuohy needle as introducer

The infiltration set contains:

  • A multi hole catheter
  • A Tuohy needle (2 lengths available) for subcutaneous tunneling.
REF-NRMULTI HOLE CATHETER STYLET SIZES TUOHY NEEDLE FILTERACCESSORIESUNITS BOX
78150DA1820G x 900 mm Typ DTeflon®18G x 150 mmYesTBA
Thread device
10
78150DB1820G x 900 mm Typ CTeflon®18G x 150 mmYesTBA
Thread device
10
Sets for continuous infiltration. with Tuohy needle as introducer

Set with introducer Alene

Sets for continuous infiltration contain:

  • Polycath multi-perforated catheter
  • Introducer
  • Connector
  • Filter 0,2μ
  • Fixator catheter

These sets allow the catheter is inserted under the best conditions for technical and safety.

REF-NRDIAMETERLENGTHSTYLETCONNECTORLENGTH OF THE DIFFUSION AREAFILTER NUMBER OF HOLES / DISTANCE UNITS/BOX
78590SB20I20G900 mmTeflon®TBA20 mmYes6 holes at a distance of 4 mm.10
78590SA20I20G900 mmTeflon®TBA66 mmYes6 holes distributed in 2 groups with 3 holes, with a distance of 4 mm between them and a distance of 50 mm between both groups.10
78590DB20I20G900 mmTeflon®TBA70 mmYes12 holes distributed in 2 groups with 6 holes, with a distance of 4 mm between them and a distance of 30 mm between both groups.10
78590DA20I20G900 mmTeflon®TBA120 mmYes12 holes distributed in 2 groups with 6 holes, with a distance of 4 mm between them and a distance of 80 mm between both groups.10
78590DG36I19G900 mmTeflon®TBA143 mmYes21 holes with a distance of 4 mm between them at a length of 143 mm.10
78590DG84I19G900 mmTeflon®TBA332 mmYes48 holes with a distance of 4 mm between them at a length of 332 mm.10
Sets for continuous infiltration. Set with introducer Alene

The standard use of Chiba Needles is for biopsies. Siliconized stainless steel of medical quality to reduce friction when inserting the needle.

ADVANTAGE

  • Easy-to-open blister pack, to prevent items from falling out when opening the blister.
  • Color code on stylet hub and packaging allowing a quick and easy identification of the size of the product.
REF-NRDIAMETERLENGTHCOLOUR CODE UNITS / BOX
95200-1818G200 mmPINK25
95200-2020G200 mmYELLOW 25
95200-2222G200 mmBLACK25
95150-2020G150 mmYELLOW25
Chiba Needles for biopsies temena

Standard ophthalmic needles can harm the cornea with the sharp edges and sharp winglets of their hub. Peribulbar and retrobulbar needles avoid any possible damage to the cornea thanks to their perfectly rounded non-traumatic hub with Luer Slip connection. These needles are equipped with a well grinded bevel offering the anesthetist greater control.

REF-NRDIAMETERLENGTH UNITS / BOX
PB 025-2525G25 mm10
peribulbar needle temena

Standard ophthalmic needles can harm the cornea with the sharp edges and sharp winglets of their hub. Peribulbar and retrobulbar needles avoid any possible damage to the cornea thanks to their perfectly rounded non-traumatic hub with Luer Slip connection. These needles are equipped with a well grinded bevel offering the anesthetist greater control.

REF-NRDIAMETER
LENGTH
UNITS / BOX
PB 035-2525G35 mm10
retrobulbar

This set it’s perfect for longer lasting ophthalmological interventions like vitrectomie or displacement of the retina. The Set contains a 22G Peribulbarneedle, which allows to introduce a 28 G PA catheter with stylet. The needle hub offers a conical entrance with a rounded edge, so it makes easy to introduce this PA-Micro catheter.

REF-NR RETROBULBAR NEEDLECATHETERSYRINGECONNECTORFILTERUNITS / BOX
PB 128-35 22 G x 35 mm 28 G x 400 mm2,5 ml LLTBA0.2μ10
Set for retrobulbar anesthesia Temena

The LOR (loss of resistance) syringe was designed to offer the anaesthetist the most enhanced reaction capacity using the Loss Of Resistance technique for detection of the epidural space.

Depending on the personal choice of each anaesthetist, the cylinder is available either in PC (Polycarbonate) or in PP (Polypoprylene).

REF-NRCOMPOSITIONCONNECTIONSYRINGE UNITS / BOX
800LL-10 Polycarbonate Luer-Lock 10 ml10
800LS-10 Polycarbonate Luer– Slip10 ml10
900LL-10 Polypropylene Luer-Lock 10 ml10
900LS-10Polypropylene Luer– Slip10 ml10
Syringe Luer Lock PC

The components of our sets are available individually.

REF-NRNAMEFUNCTIONFEATURESUNITS / BOX
26010200FilterWithholds bacterias and particlesPolysulfon 0.2 μ20
26010400Filter with skin fixationWithholds bacterias and particlesPolysulfon 0.2 μ10
091051-1TBACatheter connectorConnection10
291051Stim TBAdapterStimulating catheter connectorConnection10
26000000TransafixCatheter fixationPolyamide25
26030001Yellow extension tubeExtension tube for RAPolyethylene20
Accessories for regional anesthesia and analgesia